Sensors and data
Supported sensors
Section titled “Supported sensors”eskin reads iontronic e-skin pads with 48 × 48 taxels. All pads use the same wire protocol.
| Pad | Active area | Taxel pitch | USB interface | Frame rate | Recommended options |
|---|---|---|---|---|---|
| 20 mm pad | 20 mm × 20 mm | 0.42 mm | native USB CDC | about 56 frames/s | defaults |
| 190 mm pad | about 190 mm × 190 mm | about 4 mm | CH340 USB-to-UART bridge | about 31 frames/s | --rotate 0, --size-mm 190 |
The frame rates are measured on macOS.
Sensing principle
Section titled “Sensing principle”Each taxel is an iontronic receptor. An ionic gel with a micro-structured surface lies on the electrodes. Pressure flattens the micro-structures, the contact area increases, and the capacitance of the electric double layer at the interface increases. The readout board measures this capacitance for all 2304 taxels and sends one number for each taxel.
The technology is described in Li Z., Da B., Shi J. et al., “Large-scale iontronic skins with neural-hierarchical processing architecture”, Nature Machine Intelligence (2026), doi:10.1038/s42256-026-01325-6.
What the values mean
Section titled “What the values mean”A frame holds 2304 signed 16-bit counts in row-major order: index = row * 48 + column.
frame.rawis the count from the sensor. A larger count means more pressure.frame.valuesisraw - baseline. Values below the threshold become 0.
The 20 mm pad sends multiples of 20. The 190 mm pad sends all integer values, and its resting noise is higher: counts up to about 180 with no load.
frame.timestamp is the time when the computer decoded the frame (time.time()). The sensor does not send a timestamp.
Baseline and threshold
Section titled “Baseline and threshold”Some taxels have a resting count that is not zero. calibrate() reads 20 frames with no load and stores the maximum of each taxel as the baseline.
After that, a taxel with no load gives 0 or a negative difference, and the threshold removes it.
- The default threshold is 60 counts. A value below the threshold becomes 0.
- With
threshold=0,valueskeeps each difference that is 0 or more. A negative difference always becomes 0. - Without a baseline,
valuesisrawwith the threshold applied. Withthreshold=0,valuesis equal toraw. - Calibrate again when the resting image is not black. Temperature and a bent pad change the resting counts.
Orientation
Section titled “Orientation”The readout board sends the rows in a fixed order. The direction that is “up” in this order depends on the pad and on how you mount it.
rotate turns each frame clockwise by that number of quarter turns before the baseline is applied. It applies to raw and values.
rotate |
Result |
|---|---|
0 |
Wire order. Use this value for the 190 mm pad. |
1 (default) |
90° clockwise. Use this value for the 20 mm pad. |
2, 3 |
180° and 270° clockwise. |
To find the correct value, start eskin viz, press one corner of the pad, and compare.
Limits of the data link
Section titled “Limits of the data link”- A frame has no checksum and no sequence number. The parser checks only the header and the trailer. A frame with damaged values and a correct header and trailer is not detected.
reader.resyncscounts how many times the parser skipped bytes to find a frame. A number that increases shows lost bytes. We saw occasional lost bytes on the 190 mm pad, which sends data through a UART bridge at 2 Mbaud.