Troubleshooting
no USB serial device found; is the e-skin plugged in?
Section titled “no USB serial device found; is the e-skin plugged in?”- Make sure that the USB cable carries data. Some cables only supply power.
- Run
eskin ports. If it prints nothing, the system did not create a serial port. - On Windows with the 190 mm pad, install the CH340 driver.
- On Linux, look at
dmesgafter you connect the board.
several USB serial devices found, pass port= explicitly
Section titled “several USB serial devices found, pass port= explicitly”More than one USB serial device is connected. Select the sensor with --port or EskinReader(port=...).
To find which port is the sensor, disconnect it, run eskin ports, connect it, and run the command again.
no data from PORT within 1.0s
Section titled “no data from PORT within 1.0s”The port opened, but no bytes arrived.
- The port can be a different device. See the section above.
- Disconnect the board, connect it again, and try again.
- Do not change
baudrate. Boards with a UART bridge send data only at 2 000 000 baud.
Permission denied on Linux
Section titled “Permission denied on Linux”Add your user to the group that owns the port, then log in again:
sudo usermod -aG dialout "$USER"The picture is turned or mirrored
Section titled “The picture is turned or mirrored”Try --rotate 0, 1, 2 and 3. See Orientation.
rotate cannot correct a mirrored picture. If you see one, open an issue and include the pad model.
The resting picture is not black
Section titled “The resting picture is not black”- Remove all load and calibrate again: press re-calibrate on the page, or call
reader.calibrate(). - If single taxels flicker, increase the threshold, for example
--threshold 100.
The values lag behind the touch
Section titled “The values lag behind the touch”In blocking mode, your loop is slower than the sensor and reads old frames from the buffer.
Call reader.flush() before the read, or use background mode.
resyncs increases
Section titled “resyncs increases”Bytes are lost between the sensor and your program.
- Use a short USB cable and a port on the computer, not a hub.
- A program that is too slow to read the port also loses bytes. Use background mode.
A small number at start is normal: the reader starts in the middle of a frame.
The page shows “disconnected, retrying…”
Section titled “The page shows “disconnected, retrying…””The eskin viz process stopped. Look at the terminal for the reason, then start it again.
The reader thread stopped
Section titled “The reader thread stopped”In background mode, look at reader.error. The usual cause is that the sensor was disconnected or that a second program opened the same port.